c
2020 Sun Hydraulics 1 of 1
MODEL
DJA
ISO 05 - X&Y: Flow into workport B or out of A
CAVITY: T-5A
Flow Control, Meter-In B
Flow Control, Meter-Out A
TECHNICAL DATA
Body Type Sandwich
Interface ISO 05 - X&Y
Body Features Flow into workport B or out of A
Stack Height 63 mm
Open Cavities 1
Cavity T-5A
Model Weight 0.86 kg.
MODIFIER
6061-T651 Aluminum, Buna-N
/11 6061-T651 Aluminum, Buna-N, Clear Anodize - Per MIL
SPEC 8625F Type II, Class I
/10 6061-T651 Aluminum, Buna-N, Black Anodize - Per MIL
SPEC 8625F Type II, Class II
/S 65-45-12 Ductile Iron, Buna-N, Chem. Black
/S3 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with
Top Sealer
sunhydraulics.com/model/
DJA
NOTES
Stack height value in technical data table includes seal retainer plate.
This installation requires a retainer and seal kit which are purchased separately. See "Related Accessories" section.
Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port
type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port
type/size specified.
Model Code Example: DJA
CONFIGURATION OPTIONS